runtime: fix atsamd51 volatile usage
It was still using the (long removed) //go:volatile pragma for volatile variables, thus it was only accidentally working.
Этот коммит содержится в:
родитель
d1cc3c109d
коммит
27fafb7ab5
1 изменённых файлов: 5 добавлений и 7 удалений
|
@ -6,6 +6,7 @@ import (
|
|||
"device/arm"
|
||||
"device/sam"
|
||||
"machine"
|
||||
"runtime/volatile"
|
||||
)
|
||||
|
||||
type timeUnit int64
|
||||
|
@ -218,10 +219,7 @@ var (
|
|||
timerLastCounter uint64
|
||||
)
|
||||
|
||||
//go:volatile
|
||||
type isrFlag bool
|
||||
|
||||
var timerWakeup isrFlag
|
||||
var timerWakeup volatile.Register8
|
||||
|
||||
const asyncScheduler = false
|
||||
|
||||
|
@ -248,7 +246,7 @@ func ticks() timeUnit {
|
|||
|
||||
// ticks are in microseconds
|
||||
func timerSleep(ticks uint32) {
|
||||
timerWakeup = false
|
||||
timerWakeup.Set(0)
|
||||
if ticks < 260 {
|
||||
// due to delay waiting for the register value to sync, the minimum sleep value
|
||||
// for the SAMD51 is 260us.
|
||||
|
@ -268,7 +266,7 @@ func timerSleep(ticks uint32) {
|
|||
// enable IRQ for CMP0 compare
|
||||
sam.RTC_MODE0.INTENSET.SetBits(sam.RTC_MODE0_INTENSET_CMP0)
|
||||
|
||||
for !timerWakeup {
|
||||
for timerWakeup.Get() == 0 {
|
||||
arm.Asm("wfi")
|
||||
}
|
||||
}
|
||||
|
@ -278,7 +276,7 @@ func handleRTC() {
|
|||
// disable IRQ for CMP0 compare
|
||||
sam.RTC_MODE0.INTFLAG.SetBits(sam.RTC_MODE0_INTENSET_CMP0)
|
||||
|
||||
timerWakeup = true
|
||||
timerWakeup.Set(1)
|
||||
}
|
||||
|
||||
func initUSBClock() {
|
||||
|
|
Загрузка…
Создание таблицы